⒈目的:
The purpose of:
 分析测量系统变差,使测量系统处于受控状态,以确保过程输出所测得的数据有效可靠。
Analysis of measurement system variation, so that the measurement system in a controlled state, to ensure the process output the measured data are effective and reliable.
 ⒉范围:
The range:
 本公司生产过程中所有在用计量器具和测试设备。
The company production process all in measuring instruments and testing equipment.
 ⒊职责:
His duties:
 3·1  计量室负责测量系统分析计划的编制、测量、试验、分析统计及计量检测设备的检查、校准工作。
3 / 1 the metering chamber for measurement system analysis plan, measurement, test, statistical analysis and measuring equipment inspection, calibration work.
 3·2  生产部负责安排检测人员参加测量系统分析工作。
3 / 2 production department is responsible for the arrangement of testing personnel to participate in the measurement system analysis.
 3·3  各工段负责对在用计量检测设备的日常维护保养,并配合计量部门进行测量系统变差分析。
3 / 3 the section responsible for use in measuring equipment daily maintenance, and with the measuring department for measurement system variation analysis.
 3·4  技术部经理负责对测量系统分析计划的批准、结果的评价和适用条件的审批。
3 / 4 technical manager is responsible for the measurement system analysis plan approval, evaluation of results and the applicable conditions of approval.
 ⒋工作程序:
The work program:
4·1  编制试验计划
4 and 1 make the test plan
 4·1·1  计量员按生产过程在用计量器具和检测设备清单于每年一月上旬编制年度测量系统分析计划报技术部经理批准。
4 / 1 / 1 is measured according to the production process in the use of measuring instruments and testing equipment list in early January each year to prepare annual measurement system analysis plan report the technical department manager for approval.
 4·1·2  对下述几种情况的测量系统每年至少分析一次,且间隔不大于12个月:
4, 1, 2 for the following several cases every year at least once a measurement system analysis, and the interval is less than 12 months:
 ①控制计划中规定的测量系统;
As specified in the control plan measurement system;
4·1·3  如顾客有要求,应将顾客提出的测量系统分析试验列入计划。
4 / 1 / 3 as required by the customer, the customer should be the measurement system analysis test plan.
 4·2  试验工作准备
4 2 test preparation
 4·2·1  人员准备:
4, 2, 1 personnel preparation:
 计量员应按试验计划要求生产部确定测量试验的评价人员(人数在2-4人)和分析人员(1-2人)。
Gauger should according the test plan requirements identified measurement test for the evaluation of personnel (the number of people in the 24 ) and analysis ( 12 people ).
 4·2·2  表单和资料准备:
4 - 2 - 2 form and data preparation:
 根据试验计划,计量员应准备数据记录表、试验和有效的测试规程。
According to the test plan should be prepared, metric data record, test and effective testing procedure.
 4·2·3  计量室负责确定被测样品的数量和测试的次数:
4 / 2 / 3 the metering chamber is responsible for determining the sample to be tested and the number of test cycles:
 ①样本应在正常生产过程中选取,对R&R试验的样本一般为5-15件/人;作稳定性试验的样本一般不少于20件;作计数型量具研究用的样品按 "小样法",必须选取含超差的样品(一般为20件);
The samples should be in the normal production process selection, to RR test sample is generally 515 member / person; stability test sample is generally not less than 20; for counting measuring study using samples according to the" sample", must be selected with the ultra difference samples (usually 20 );
 ②作R&R试验的次数一般为3次,人数2-4人。
II as RR test time is generally 3 times the number of people, 24.
 4·2·4  试验准备工作完成后,计量室应提前二天通知给相应部门和人员。
4 - 2 4 test preparation is completed, the metering chamber two days notice should be given to the relevant departments and personnel.
 4·3  测量试验的实施
4 / 3 the implementation of measurement test
 4·3·1  测量系统分析研究人员应在测量前对测量仪器的分辨力及测量操作规程的资料进行有效性检查,对待测样品进行编号。
4 3 1 measurement system analysis personnel should be measured before the resolution of a measuring instrument and measuring procedure of data validity check, measure the sample number.
 4·3·2  测量系统评价人员各自按相关检测操作规程对已编号的样品独立进行测试,由测量系统分析人员将结果记录在数据表上。